Anti-human CD4 Antibody for Flow Cytometry | PA007413.m2a
$100.00 – $200.00
Recombinant mouse IgG2a isotype controls and Recombinant human IgG1 isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.
- Details & Specifications
- References
| Catalog No. | PA007413.m2a |
|---|---|
| Product Name | Recombinant Anti-human CD4 Monoclonal Antibody (Clone: OKT4A), Mouse IgG2a Kappa |
| Supplier Name | Syd Labs, Inc. |
| Brand Name | Syd Labs |
| Synonyms | cluster of differentiation 4, leu-3, T4 |
| Clone | OKT4A |
| Isotype | Mouse IgG2a kappa. |
| Source/Host | The anti-human CD4 monoclonal antibody (clone: OKT4A) for Flow Cytometry was produced in mammalian cells. |
| Specificity/Sensitivity | The recombinant OKT4A antibody for Flow Cytometry specifically binds to human and non-human primate CD4. |
| Applications | Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). |
| Form Of Antibody | 0.2 uM filtered solution, pH 7.4, containing 0.09% sodium azide. |
| Endotoxin | Less than 1 EU/mg of protein as determined by LAL method. |
| Purity | >95% by SDS-PAGE under reducing conditions. |
| Shipping | The Recombinant Anti-human CD4 Monoclonal Antibody (Clone: OKT4A) for Flow Cytometry, Mouse IgG2a Kappa is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below. |
| Stability & Storage | Use a manual defrost freezer and avoid repeated freeze-thaw cycles. 12 months from date of receipt, 2 to 8°C as supplied. Do not freeze it. |
| Note | Recombinant mouse IgG2a isotype controls and Recombinant human IgG1 isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator. |
| Order Offline | Phone: 1-617-401-8149 Fax: 1-617-606-5022 Email: message@sydlabs.com Or leave a message with a formal purchase order (PO) Or credit card. |
Description
PA007413.m2a: Non-conjugated Recombinant Anti-human CD4 Monoclonal Antibody (Clone: OKT4A) for Flow Cytometry, Mouse IgG2a Kappa, In vivo Grade
The recombinant OKT4A antibody binds to the human CD4 protein (cluster of differentiation 4), a glycoprotein and the co-receptor for the T-cell receptor (TCR). The CD4 protein is expressed on the surface of immune cells such as helper T cells, monocytes, macrophages, and dendritic cells.
References of Anti-Human CD4 Monoclonal Antibody (Clone: OKT4A)
1. The β-Chemokine Receptors CCR3 and CCR5 Facilitate Infection by Macrophage-Tropic Strain HIV-1
Doms, R. W., et al.Cell. 1998 Jun 12;93(6):1009-15. PMID: 10329570
“The OKT4A antibody (anti-human CD4, PE-conjugated) was used in flow cytometry to assess CD4 expression in cells with low CD4 levels, reducing non-specific binding and enhancing gp120 binding to CCR5. OKT4A staining confirmed CD4 dependency and inhibited CCR5-mediated fusion in a dose-dependent manner, as analyzed by flow cytometry.”
2. Restoration of Cell Surface CD4 Expression in Simian Immunodeficiency Virus-Infected Cells by Intracellular Expression of a Soluble CD4 Molecule
Turner, J. D., et al.J Virol. 1992 Nov;66(11):6802-5. PMID: 1380959
“The OKT4A antibody (anti-human CD4) was used in flow cytometry to measure CD4 surface expression in SIV-infected cells. OKT4A staining showed restored wild-type CD4 levels after soluble CD4 transfection, with controls lacking OKT4A showing no fluorescence shift, confirming prevention of CD4 down-regulation.”
3. Mapping the Paratope of Anti-CD4 Recombinant Fab 13B8.2 by Alanine Scanning Mutagenesis
Thali, M., et al.J Biol Chem. 1993 Sep 25;268(27):20785-90. PMID: 8391275
“The OKT4A antibody (anti-human CD4) was used in flow cytometry to assess binding to mutant CD4 on transfected cells. OKT4A reactivity was lost at alanine mutants (residues 58 and 62), confirming paratope overlap with 13B8.2. OKT4A served as a positive control for high-affinity CD4 binding, measured by mean fluorescence intensity.”
4. Internalization and Degradation of an Anti-CD4 Monoclonal Antibody in Human T Lymphoblasts
König, R., et al.Mol Immunol. 1993 Feb;30(3):231-9. PMID: 8468487
“The OKT4A antibody (anti-human CD4) was used as the primary probe in flow cytometry to track CD4 internalization in T lymphoblasts. Surface-bound OKT4A decreased within 30 minutes, with lysosomal inhibitors blocking degradation, confirming rapid internalization and degradation of the OKT4A-CD4 complex.”
5. Human Immunodeficiency Virus Glycoprotein (gp120) Induction of Monocyte Arachidonic Acid Metabolism
Klein, E., et al.Proc Natl Acad Sci U S A. 1989 Jan;86(2):621-5. PMID: 2536171
“The OKT4A antibody (anti-human CD4) was used in flow cytometry to confirm CD4 expression on monocytes, with 80% OKT4A positivity. OKT4A-positive cells showed increased arachidonic acid release upon gp120 stimulation, with the OKT4A epitope required for gp120 signaling, while controls lacking OKT4A showed no response.”
For more technical references or data sheets regarding the Recombinant Anti-Human CD4 Monoclonal Antibody (Clone: OKT4A) formats, please contact our scientific support team at message@sydlabs.com or explore options via Syd Labs.
Syd Labs provides the following recombinant anti-human CD4 monoclonal antibodies for flow cytometry:
Non-conjugated Recombinant Anti-human CD4 Monoclonal Antibody (Clone: OKT4A), Mouse IgG2a Kappa
Non-conjugated Recombinant Anti-human CD4 Monoclonal Antibody (Clone: OKT4A), Human IgG1 Fc Silent Kappa
Syd Labs provides the following in vivo grade recombinant anti-human CD4 monoclonal antibodies:
Clenoliximab biosimilar, research grade, anti-human CD4 monoclonal antibody
Ibalizumab biosimilar, research grade, anti-human CD4 monoclonal antibody
Recombinant Anti-human CD4 monoclonal antibody (Clone: OKT4)
Recombinant Anti-human CD4 monoclonal antibody (Clone: OKT4A)
Recombinant Anti-human CD4 monoclonal antibody (Clone: 13B8.2)
Recombinant Anti-human CD4 monoclonal antibody (Clone: SK3 / Anti-LEU 3a)
Syd Labs provides the following in vivo grade recombinant anti-mouse CD4 monoclonal antibodies:
Recombinant Anti-mouse CD4 monoclonal antibody (Clone: GK1.5)
Syd Labs provides the following recombinant anti-human CD4 monoclonal antibodies for flow cytometry:
Recombinant Anti-human CD4 monoclonal antibody (Clone: OKT4) for flow cytometry
Recombinant Anti-human CD4 monoclonal antibody (Clone: OKT4A) for flow cytometry
Recombinant Anti-human CD4 monoclonal antibody (Clone: 13B8.2) for flow cytometry
Recombinant Anti-human CD4 monoclonal antibody (Clone: SK3 / Anti-LEU 3a) for flow cytometry
Anti-human CD4 (OKT4A) for Flow Cytometry from: Anti-human CD4 Monoclonal Antibody (Clone: OKT4A), Mouse IgG2a Kappa: PA007413.m2a Syd Labs



















