Anti-Human CD28 Antibody (Clone: 9.3) | PA007458
$150.00 – $900.00
Recombinant Mouse IgG2a isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.
- Details & Specifications
- References
| Catalog No. | PA007458 |
|---|---|
| Product Name | In vivo Grade Recombinant Anti-Human CD28 Monoclonal Antibody, Mouse IgG2a Kappa (Clone: 9.3) |
| Data Sheet | 📄 Download Product Data Sheet (PDF) |
| Supplier Name | Syd Labs, Inc. |
| Brand Name | Syd Labs |
| Synonyms | T-cell-specific surface glycoprotein CD28; TP44 |
| Clone | 9.3. |
| Isotype | Mouse IgG2a Kappa. |
| Specificity/Sensitivity | The in vivo grade recombinant mouse monoclonal antibody (clone: 9.3) specifically binds to mouse CD28. |
| Applications | ELISA, flow cytometry, neutralization, functional assays such as bioanalytical PK and ADA assays, and those assays for studying biological pathways affected by the mouse CD28 protein. |
| Form Of Antibody | 0.2 μM filtered solution of 1x PBS. |
| Endotoxin | Less than 1 EU/mg of protein as determined by LAL method. |
| Purity | >95% by SDS-PAGE under reducing conditions. |
| Shipping | The in vivo grade recombinant anti-human CD28 antibodies (clone of 9.3) are shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below. |
| Stability & Storage | Use a manual defrost freezer and avoid repeated freeze-thaw cycles. 12 months from date of receipt, -20 to -70°C as supplied. 1 month from date of receipt, 2 to 8°C as supplied. |
| Note | Recombinant Mouse IgG2a isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator. |
| Order Offline | Phone: 1-617-401-8149 Fax: 1-617-606-5022 Email: message@sydlabs.com Or leave a message with a formal purchase order (PO) Or credit card. |
Description
PA007458: Recombinant Anti-Human CD28 Monoclonal Antibody (Clone: 9.3), Mouse IgG2a Kappa , In vivo Grade
The in vivo grade recombinant anti-human CD28 Mouse IgG2a Kappa monoclonal antibody was produced in mammalian cells.
References of Anti-Human CD28 Monoclonal Antibody (Clone: 9.3)
1. Profiling T cell activation using single-molecule fluorescence in situ hybridization and flow cytometry.
Bushkin, Y., et al.J Immunol. 2015 Jan 15;194(2):836-41. doi: 10.4049/jimmunol.1401515. PMID: 25505292
“Flow cytometric characterization of Ag-specific T cells typically relies on detection of protein analytes. …Shifting the analysis to detection of RNA would provide several significant advantages, which we illustrate by developing a new host immunity-based platform for detection of infections. …Cytokine mRNAs synthesized in response to ex vivo stimulation with pathogen-specific Ags are detected in T cells with single-molecule fluorescence in situ hybridization followed by flow cytometry. …Background from pre-existing in vivo analytes is lower for RNAs than for proteins, allowing greater sensitivity for detection of low-frequency cells. …The utility of probing immunological memory of infections is demonstrated by detecting T cells that recognize mycobacterial and viral Ags in donors exposed to the respective pathogens.”
2. Glycogen synthase kinase-3 controls IL-10 expression in CD4(+) effector T-cell subsets through epigenetic modification of the IL-10 promoter.
Hill, E. V., et al.Eur J Immunol. 2015 Apr;45(4):1103-15. doi: 10.1002/eji.201444661. PMID: 25627813
“To investigate the requirement for APCs during GSK3 inhibition mediated induction of IL-10 in CD4+ T cells, naive or polarized Tg4 CD4+ T cells were cultured with anti-CD3/ anti-CD28 stimulation in the presence of GSK3 inhibitors and IL-10 secretion was assessed. …(A) Naive CD4+ T cells were isolated from Tg4 splenocytes and cultured with anti-CD3 and anti-CD28 in the presence of IL-2 and GSK3 inhibitors or vehicle control. …NS, not significant (ANOVA). (B) Th1 polarized Tg4 cells were restimulated with anti-CD3 and anti-CD28 in the presence of IL-2 and GSK3 inhibitors or vehicle control. …Alternatively, live CD4+ T cells were isolated by Ficoll centrifugation and then magnetic separation using the CD4+ T cell Isolation kit II and restimulated with either anti-CD3 and anti-CD28 coated beads (Dynabeads, Life Technologies) or on anti-CD3 (1 µg/mL, eBioscience; clone 145-2C11) and anti-CD28 (2 µg/mL, eBioscience; clone 37.51) coated plates. …Total mRNA from 3-5 × 10^6 CD4+ T cells after overnight anti-CD3 and anti-CD28 stimulation was isolated using RNAeasy Mini Kit (Qiagen) and quality and quantity were verified using a Nanodrop (Thermo scientific).”
For more technical references or data sheets regarding the Recombinant Anti-Human CD28 Monoclonal Antibody (Clone: 9.3) formats, please contact our scientific support team at message@sydlabs.com.
Related Recombinant IgG Reference Antibodies:
Recombinant mouse IgG2a isotype control antibody, In vivo grade
Syd Labs provides the following recombinant anti-human CD28 monoclonal antibodies:
Recombinant anti-human CD28 antibodies (clone 15E8), In vivo grade
Recombinant anti-human CD28 antibodies (clone 9.3), In vivo grade
Recombinant anti-human CD28 antibodies (clone CD28.3), In vivo grade
Syd Labs provides the following recombinant anti-mouse CD28 monoclonal antibodies:
Recombinant anti-mouse CD28 antibodies (clone PV-1), In vivo grade
Anti-Human CD28 (9.3) from: In vivo Grade Recombinant Anti-Human CD28 Monoclonal Antibody : PA007458 Syd Labs