Anti-mouse CD3 Antibody for Flow Cytometry | PA007254.r2b
$40.00 – $80.00
Recombinant rat IgG2b isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.
- Details & Specifications
- References
| Catalog No. | PA007254.r2b |
|---|---|
| Product Name | Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2), Rat IgG2b Kappa |
| Supplier Name | Syd Labs, Inc. |
| Brand Name | Syd Labs |
| Synonyms | cluster of differentiation 3, CD3D, CD3E, CD3G |
| Summary | The recombinant anti-mouse CD3 monoclonal antibody (clone: 17A2) was produced in mammalian cells. |
| Clone | 17A2. |
| Isotype | Rat IgG2b kappa. |
| Source/Host | The recombinant anti-mouse CD3 monoclonal antibody (clone: 17A2) for Flow Cytometry was produced in mammalian cells. |
| Specificity/Sensitivity | The recombinant 17A2 antibody for Flow Cytometry specifically binds to the mouse T cell receptor CD3. |
| Applications | Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). |
| Form Of Antibody | 0.2 uM filtered solution, pH 7.4, containing 0.09% sodium azide. |
| Conjugate | Non-conjugated. |
| Purity | >95% by SDS-PAGE under reducing conditions and HPLC. |
| Shipping | The Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2) for Flow Cytometry, Rat IgG2b Kappa is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below. |
| Stability & Storage | Use a manual defrost freezer and avoid repeated freeze-thaw cycles. 12 months from date of receipt, 2 to 8°C as supplied. Do not freeze it. |
| Note | Recombinant rat IgG2b isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator. |
| Order Offline | Phone: 1-617-401-8149 Fax: 1-617-606-5022 Email: message@sydlabs.com Or leave a message with a formal purchase order (PO) Or credit card. |
Description
PA007254.r2b: Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2) for Flow Cytometry, Rat IgG2b Kappa
The 17A2 antibody binds to CD3 epsilon of the T cell receptor-CD3 complex found only on mature T cells and medullary thymocytes.
References of Anti-Mouse CD3 Monoclonal Antibody (Clone: 17A2)
1. Inhibition of T cell-mediated inflammation in uveitis by a novel anti-CD3 antibody
Sugita S, Shimizu J, Makabe K, Keino H, et al.Arthritis Res Ther. 2017 Jul 25;19(1):176. PMID: 28743289
“In brief, CFSE-labeled C57BL/6JJcl splenocytes (2 × 10^6 cells/well) and irradiated (20 Gy) BALB/c splenocytes (2 × 10^5 cells/well) were cocultured in 24-well plates with 1 μg/ml of Dow2, a control anti-mouse CD3 ε Ab (clone 17A2), or an isotype control (rat IgG)…Mouse pan-T cells isolated from C57BL/6JJcl donors were incubated with 1 μg/ml of Dow2 or a control anti-mouse CD3 Ab (clone 17A2 or clone 145-2C11) at 4 °C for 30 min…Incubation with Dow2 alone or rat IgG did not stimulate T cells to produce detectable IFN-γ (Fig. 2b, left panel) or IL-17 (Fig. 2c, left panel). In contrast, T cells incubated with 17A2 (anti-mouse CD3 antibody) produced increased levels of cytokines which were significantly reduced in T cells incubated with both Dow2 and 17A2 (anti-mouse CD3 mAb)…In contrast, IRBP-stimulated production of IFN-γ was significantly enhanced in ocular cells incubated with 17A2 antibody (P < 0.005)…The expression of CD4 and CD8 on splenocytes from normal control mice and Dow2- or rat IgG-treated EAU mice was assessed by flow cytometry.”
2. In vivo Imaging Technologies to Monitor the Immune System
McCarthy CE, White JM, Viola NT, Gibson HM.Front Immunol. 2020 Jun 2;11:1067. PMID: 32582173
“Upon ex vivo analysis, one study reported a relative depletion of CD4 T cells and an expansion of CD8 T cells after delivery of an 89Zr-anti-CD3 tracer (clone 17A2) in mice…Conjugation of the contrast material to an antibody allows for specific targeting of a cell population or protein of interest…Protein platforms including antibodies, cytokines, and receptor ligands are also popular choices as molecular imaging agents for positron emission tomography (PET), single-photon emission computerized tomography (SPECT), scintigraphy, and optical imaging…Promising new adoptive cell therapies (ACT) for cancer, including ex vivo expanded tumor-infiltrating lymphocytes (TILs) and chimeric antigen receptor T cells (CAR-T cells), would benefit from imaging technologies that track cell fate in vivo…CD8 + cytotoxic T lymphocytes (CTLs) specific to the melanoma antigen Melan-A were 111In-labeled, infused in patients, and evaluated using serial whole body and static gamma camera imaging.”
3. Quantitative CD3 PET Imaging Predicts Tumor Growth Response to Anti-CTLA-4 Therapy
Larimer BM, Wehrenberg-Klee E, Caraballo A, Mahmood U.J Nucl Med. 2016 Oct;57(10):1607-1611. PMID: 27230929
“The monoclonal antimouse CD3 antibody clone 17A2 was purchased from…Conjugation and radiolabeling of the CD3 antibody resulted in a pure, highly specific probe for CD3-expressing cells…For Western blotting, the tumors were lysed in 1% sodium dodecyl sulfate and subjected to sodium dodecyl sulfate–polyacrylamide gel electrophoresis…Blots were transferred to nitrocellulose, blocked with 5% nonfat dry milk, and probed with the appropriate antibodies…Immunohistochemical staining was performed on formalin-fixed, paraffin-embedded 10-μm slices of tumor to confirm the cellular location of CD3 expression.
For more technical references or data sheets regarding the Recombinant Anti-Mouse CD3 Monoclonal Antibody (Clone: 17A2) formats, please contact our scientific support team at message@sydlabs.com or explore options via Syd Labs.
Syd Labs provides the following anti-mouse CD3 antibodies for flow cytometry:
Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
Biotin Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
FITC Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
APC Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
PE Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
Pacific Blue Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
PerCP Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
PE/Cy5 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
PE/Cy7 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
iFluor 488 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
iFluor 549 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
iFluor 594 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
iFluor 647 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
iFluor 700 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
APC/Cy7 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
PerCP/Cy5.5 Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2)
Syd Labs provides the following recombinant anti-mouse CD3 antibodies for flow cytometry:
Recombinant Anti-mouse CD3 monoclonal antibody (Clone: 17A2) for flow cytometry
Recombinant Anti-mouse CD3e monoclonal antibody (Clone: 145-2C11) for flow cytometry
Syd Labs provides the following recombinant anti-human CD3 antibodies for flow cytometry:
Recombinant Anti-human CD3 monoclonal antibody (Clone: OKT3) for flow cytometry
Recombinant Anti-human CD3 monoclonal antibody (Clone: UCHT1) for flow cytometry
Syd Labs also provides the following in vivo grade recombinant anti-mouse CD3 antibodies:
Recombinant Anti-mouse CD3e monoclonal antibody (Clone: 145-2C11)
Recombinant Anti-mouse CD3e monoclonal antibody (Clone: 500A2)
Recombinant Anti-mouse CD3 monoclonal antibody (Clone: 17A2)
Syd Labs provides the following in vivo grade recombinant anti-human CD3 antibodies:
Recombinant Anti-human CD3 monoclonal antibody (Clone: OKT3)
Recombinant Anti-human CD3 monoclonal antibody (Clone: SP34-2)
Recombinant Anti-human CD3 monoclonal antibody (Clone: UCHT1)
Anti-mouse CD3 Antibody (17A2) for Flow Cytometry from: Recombinant Anti-mouse CD3 Monoclonal Antibody (Clone: 17A2), Rat IgG2b Kappa: PA007254.r2b Syd Labs





















