Anti-human HLA-ABC Antibody for Flow Cytometry | PA007472.m2a

Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Mouse IgG2a Kappa PA007472.m2a Syd Labs

Anti-human HLA-ABC Antibody for Flow Cytometry | PA007472.m2a

$45.00 – $90.00

In stock

$45.00 – $90.00

Recombinant Mouse IgG2a isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.

    Clear
    View cart
    Catalog No. PA007472.m2a
    Product Name Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Mouse IgG2a Kappa
    Supplier Name Syd Labs, Inc.
    Brand Name Syd Labs
    Synonyms Major Histocompatibility Class I, MHC class I, human leukocyte antigen (HLA), HLA class I histocompatibility antigen
    Clone W6/32.
    Isotype Mouse IgG2a Kappa.
    Source/Host The anti-human HLA-ABC monoclonal antibody (clone: W6/32) for Flow Cytometry was produced in mammalian cells.
    Specificity/Sensitivity The recombinant W6/32 antibody for Flow Cytometry specifically binds to mouse HLA-ABC.
    Applications Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F).
    Form Of Antibody 0.2 uM filtered solution, pH 7.4, containing 0.09% sodium azide.
    Conjugate Non-conjugated.
    Purity >95% by SDS-PAGE under reducing conditions.
    Shipping The Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32) for Flow Cytometry, Mouse IgG2a Kappa is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below.
    Stability & Storage Use a manual defrost freezer and avoid repeated freeze-thaw cycles. 12 months from date of receipt, 2 to 8°C as supplied. Do not freeze it.
    Note Recombinant Mouse IgG2a isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.
    Order Offline Phone: 1-617-401-8149 Fax: 1-617-606-5022 Email: message@sydlabs.com Or leave a message with a formal purchase order (PO) Or credit card.

    Description

    PA007472.m2a: Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32) for Flow Cytometry, Mouse IgG2a Kappa, In vivo Grade

    References of Anti-Human HLA-ABC Monoclonal Antibody (Clone: W6/32)

    1. Mass spectrometric profiling of HLA-B44 peptidomes provides evidence for tapasin-mediated tryptophan editing
    Kaur A, et al.J Immunol. 2023. PMID: 37737643
    “This study uses mass spectrometry to explore tapasin-mediated tryptophan editing in HLA-B44 peptidomes. The W6/32 antibody (anti-human HLA-ABC) was purified from mouse ascites and crosslinked to PureProteome Protein A magnetic beads for immunoaffinity purification. Cells were stained with W6/32-FITC antibody for surface HLA class I analysis via quantitative flow cytometry, revealing a significant reduction in HLA-B44:05 molecules on tapasin knockout cells compared to wild-type cells. A slight, non-significant decrease in HLA-B44:05 surface stability was observed in tapasin knockout cells in the presence of brefeldin A.”

    2. Inhibition of major histocompatibility complex-I antigen presentation by sarbecovirus ORF7a proteins
    Zhang F, et al.Proc Natl Acad Sci U S A. 2022. PMID: 36136978
    “This study investigates how sarbecovirus ORF7a proteins inhibit MHC-I antigen presentation. Human 293T, HuH7.5, U2OS, and A549/ACE2 cells were transduced with lentiviral vectors expressing SARS-CoV-2 ORF7a or Nef and stained with the pan-HLA-ABC antibody W6/32 for flow cytometry. MHC-I surface levels, measured by median fluorescence intensity, were reduced in ORF7a-expressing cells. The study compared wild-type and ORF7-deleted SARS-CoV-2 strains, confirming ORF7a’s role in suppressing MHC-I expression.”

    3. Assessments of HLA-I Specificities of Anti-HLA-I Monoclonal Antibodies Using Solid Phase Bead Arrays
    Zaitouna AJ, et al.Bio Protoc. 2020. PMID: 33659325
    “This study evaluates anti-HLA-I monoclonal antibody specificities using solid phase bead arrays. The W6/32 antibody, a pan anti-HLA class I antibody, was used to normalize HLA-I protein levels on Labscreen and FlowPRA Single Antigen Beads. Biotinylated W6/32 was tested at various dilutions (undiluted to 1:100) alongside anti-Bw4 and anti-Bw6 antibodies. Representative data showed W6/32 binding to HLA-I beads, with isotype control IgG2a used for comparison.”

    4. Strategies for the measurements of expression levels and half-lives of HLA class I allotypes
    Raghavan M, et al.Hum Immunol. 2019. PMID: 30735755
    “This study describes methods for measuring HLA class I expression and half-lives using the W6/32 antibody (anti-human HLA-ABC). Flow cytometry histograms showed W6/32 signals for monocytes, NK cells, B cells, CD8+ T cells, and CD4+ T cells, with geometric mean values quantifying HLA class I expression. The W6/32 antibody was chosen for its broad recognition of most HLA class I allotypes, facilitating consistent assessment across healthy donors.”

    5. Higher human lymphocyte antigen class I expression in early-stage cancer cells leads to high sensitivity for cytotoxic T lymphocytes
    Akazawa Y, et al.Cancer Sci. 2019. PMID: 30973665
    “This study examines HLA class I expression in early-stage hepatocellular carcinoma (HCC) using the W6/32 antibody (anti-human HLA-ABC). Flow cytometry analysis of tissue from five HCC patients compared HLA class I expression between cancer cells and non-tumorous hepatocytes. The mean fluorescence intensity ratio of W6/32 staining indicated higher HLA class I expression in cancer cells, enhancing sensitivity to cytotoxic T lymphocytes. Heterogeneous expression was observed in non-tumorous hepatocytes in one case.”

    For more technical references or data sheets regarding the Recombinant Anti-Human HLA-ABC Monoclonal Antibody (Clone: W6/32) formats, please contact our scientific support team at message@sydlabs.com or explore options via Syd Labs.

    Syd Labs provides the following recombinant anti-human HLA-ABC monoclonal antibodies for flow cytometry:

    Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Mouse IgG2a Kappa
    Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Human IgG1 Fc Silent Kappa

    Syd Labs provides the following in vivo grade recombinant anti-human HLA-ABC monoclonal antibodies:

    Recombinant Anti-human HLA-ABC monoclonal antibody (Clone: W6/32)

    Anti-human HLA-ABC ( W6/32 ) for Flow Cytometry from : Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Mouse IgG2a Kappa: PA007472.m2a Syd Labs