Anti-human HLA-ABC Antibody for Flow Cytometry | PA007472.h1Fs
$45.00 – $90.00
Recombinant Human IgG1 isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.
- Details & Specifications
- References
| Catalog No. | PA007472.h1Fs |
|---|---|
| Product Name | Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Human IgG1 Fc Silent Kappa |
| Supplier Name | Syd Labs, Inc. |
| Brand Name | Syd Labs |
| Synonyms | Major Histocompatibility Class I, MHC class I, human leukocyte antigen (HLA), HLA class I histocompatibility antigen |
| Clone | W6/32. |
| Isotype | Human IgG1 kappa. |
| Source/Host | The anti-human HLA-ABC monoclonal antibody (clone: W6/32) for Flow Cytometry was produced in mammalian cells. |
| Specificity/Sensitivity | The recombinant W6/32 antibody for Flow Cytometry specifically binds to mouse HLA-ABC. |
| Applications | Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F). |
| Form Of Antibody | 0.2 uM filtered solution, pH 7.4, containing 0.09% sodium azide. |
| Conjugate | Non-conjugated. |
| Purity | >95% by SDS-PAGE under reducing conditions. |
| Shipping | The Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32) for Flow Cytometry, Human IgG1 Fc Silent Kappa is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below. |
| Stability & Storage | Use a manual defrost freezer and avoid repeated freeze-thaw cycles. 12 months from date of receipt, 2 to 8°C as supplied. Do not freeze it. |
| Note | Recombinant Human IgG1 isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator. |
| Order Offline | Phone: 1-617-401-8149 Fax: 1-617-606-5022 Email: message@sydlabs.com Or leave a message with a formal purchase order (PO) Or credit card. |
Description
PA007472.h1Fs: Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32) for Flow Cytometry, Human IgG1 Fc Silent Kappa, In vivo Grade
References of Anti-Human HLA-ABC Monoclonal Antibody (Clone: W6/32)
1. Mass spectrometric profiling of HLA-B44 peptidomes provides evidence for tapasin-mediated tryptophan editing
Kaur A, et al.J Immunol. 2023. PMID: 37737643
“This study uses mass spectrometry to explore tapasin-mediated tryptophan editing in HLA-B44 peptidomes. The W6/32 antibody (anti-human HLA-ABC) was purified from mouse ascites and crosslinked to PureProteome Protein A magnetic beads for immunoaffinity purification. Cells were stained with W6/32-FITC antibody for surface HLA class I analysis via quantitative flow cytometry, revealing a significant reduction in HLA-B44:05 molecules on tapasin knockout cells compared to wild-type cells. A slight, non-significant decrease in HLA-B44:05 surface stability was observed in tapasin knockout cells in the presence of brefeldin A.”
2. Inhibition of major histocompatibility complex-I antigen presentation by sarbecovirus ORF7a proteins
Zhang F, et al.Proc Natl Acad Sci U S A. 2022. PMID: 36136978
“This study investigates how sarbecovirus ORF7a proteins inhibit MHC-I antigen presentation. Human 293T, HuH7.5, U2OS, and A549/ACE2 cells were transduced with lentiviral vectors expressing SARS-CoV-2 ORF7a or Nef and stained with the pan-HLA-ABC antibody W6/32 for flow cytometry. MHC-I surface levels, measured by median fluorescence intensity, were reduced in ORF7a-expressing cells. The study compared wild-type and ORF7-deleted SARS-CoV-2 strains, confirming ORF7a’s role in suppressing MHC-I expression.”
3. Assessments of HLA-I Specificities of Anti-HLA-I Monoclonal Antibodies Using Solid Phase Bead Arrays
Zaitouna AJ, et al.Bio Protoc. 2020. PMID: 33659325
“This study evaluates anti-HLA-I monoclonal antibody specificities using solid phase bead arrays. The W6/32 antibody, a pan anti-HLA class I antibody, was used to normalize HLA-I protein levels on Labscreen and FlowPRA Single Antigen Beads. Biotinylated W6/32 was tested at various dilutions (undiluted to 1:100) alongside anti-Bw4 and anti-Bw6 antibodies. Representative data showed W6/32 binding to HLA-I beads, with isotype control IgG2a used for comparison.”
4. Strategies for the measurements of expression levels and half-lives of HLA class I allotypes
Raghavan M, et al.Hum Immunol. 2019. PMID: 30735755
“This study describes methods for measuring HLA class I expression and half-lives using the W6/32 antibody (anti-human HLA-ABC). Flow cytometry histograms showed W6/32 signals for monocytes, NK cells, B cells, CD8+ T cells, and CD4+ T cells, with geometric mean values quantifying HLA class I expression. The W6/32 antibody was chosen for its broad recognition of most HLA class I allotypes, facilitating consistent assessment across healthy donors.”
5. Higher human lymphocyte antigen class I expression in early-stage cancer cells leads to high sensitivity for cytotoxic T lymphocytes
Akazawa Y, et al.Cancer Sci. 2019. PMID: 30973665
“This study examines HLA class I expression in early-stage hepatocellular carcinoma (HCC) using the W6/32 antibody (anti-human HLA-ABC). Flow cytometry analysis of tissue from five HCC patients compared HLA class I expression between cancer cells and non-tumorous hepatocytes. The mean fluorescence intensity ratio of W6/32 staining indicated higher HLA class I expression in cancer cells, enhancing sensitivity to cytotoxic T lymphocytes. Heterogeneous expression was observed in non-tumorous hepatocytes in one case.”
For more technical references or data sheets regarding the Recombinant Anti-Human HLA-ABC Monoclonal Antibody (Clone: W6/32) formats, please contact our scientific support team at message@sydlabs.com or explore options via Syd Labs.
Syd Labs provides the following recombinant anti-human HLA-ABC monoclonal antibodies for flow cytometry:
Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Mouse IgG2a Kappa
Recombinant Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Human IgG1 Fc Silent Kappa
Syd Labs provides the following in vivo grade recombinant anti-human HLA-ABC monoclonal antibodies:
Recombinant Anti-human HLA-ABC monoclonal antibody (Clone: W6/32)
Anti-human HLA-ABC ( W6/32 ) for Flow Cytometry from : Anti-human HLA-ABC Monoclonal Antibody (Clone: W6/32), Human IgG1 Fc Silent Kappa: PA007472.h1Fs Syd Labs











