Anti-human CD34 Antibody for Flow Cytometry | PA007473.m1

Recombinant Anti-human CD34 Monoclonal Antibody (Clone: QBEnd/10), Mouse IgG1 Kappa PA007473.m1 Syd Labs

Anti-human CD34 Antibody for Flow Cytometry | PA007473.m1

$100.00 – $200.00

In stock

$100.00 – $200.00

Recombinant Mouse IgG1 isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.

Clear
View cart
Catalog No. PA007473.m1
Product Name Recombinant Anti-human CD34 Monoclonal Antibody (Clone: QBEnd/10), Mouse IgG1 Lambda
Supplier Name Syd Labs, Inc.
Brand Name Syd Labs
Synonyms CD34; CD34 antigen; CD34 molecule
Clone QBEnd/10.
Isotype Mouse IgG1 Kappa.
Source/Host The anti-human CD34 monoclonal antibody (clone: QBEnd/10) for Flow Cytometry was produced in mammalian cells.
Specificity/Sensitivity The recombinant QBEnd/10 antibody for Flow Cytometry specifically binds to mouse CD34.
Applications Flow cytometry (FC), and Immunohistochemistry - Frozen (IHC-F).
Form Of Antibody 0.2 uM filtered solution, pH 7.4, containing 0.09% sodium azide.
Conjugate Non-conjugated.
Purity >95% by SDS-PAGE under reducing conditions.
Shipping The Recombinant Anti-human CD34 Monoclonal Antibody (Clone: QBEnd/10) for Flow Cytometry, Mouse IgG1 Kappa is shipped with ice pack. Upon receipt, store it immediately at the temperature recommended below.
Stability & Storage Use a manual defrost freezer and avoid repeated freeze-thaw cycles. 12 months from date of receipt, 2 to 8°C as supplied. Do not freeze it.
Note Recombinant Mouse IgG1 isotype controls are available. Condition of sample preparation and optimal sample dilution should be determined experimentally by the investigator.
Order Offline Phone: 1-617-401-8149 Fax: 1-617-606-5022 Email: message@sydlabs.com Or leave a message with a formal purchase order (PO) Or credit card.

Description

PA007473.m1: Recombinant Anti-human CD34 Monoclonal Antibody (Clone: QBEnd/10) for Flow Cytometry, Mouse IgG1 Kappa, In vivo Grade

References of Anti-Human CD34 Monoclonal Antibody (Clone: QBEnd/10)

1. Flow cytometric enumeration of CD34+ hematopoietic stem cells using QBEnd/10 and other clones: a comparative study
Sutherland DR, et al.Cytometry. 2000 Jan 1;40(1):1-10. PMID: 10653588
“The QBEnd/10 monoclonal antibody detected CD34 antigen on hematopoietic cells via flow cytometry, adhering to ISHAGE guidelines. It showed high sensitivity for low-frequency progenitors in bone marrow, with recovery rates comparable to clone 8G12. Quality control used isotype controls and 7-AAD viability staining.”

2. Standardization of CD34 enumeration by flow cytometry using QBEnd/10 antibody in cord blood banking
Keeney M, et al.Transfusion. 2001 Sep;41(9):1101-10. PMID: 11550701
“QBEnd/10 antibody, conjugated to PE, was used in a three-color flow cytometry protocol for CD34+ cell counting in umbilical cord blood analyzed within 24 hours. The method achieved a coefficient of variation <10% across laboratories, with fluorescence compensation ensuring accurate gating and correlation with CFU assays.”

3. Comparative evaluation of anti-CD34 antibodies including QBEnd/10 for flow cytometric analysis of mobilized peripheral blood stem cells
Hesselton RM, et al.Cytotherapy. 2002;4(1):1-9. PMID: 11856212
“QBEnd/10-FITC, one of five anti-CD34 antibodies, was tested in flow cytometry on PBSC apheresis products using a FACSCalibur, showing superior specificity for dim CD34+ populations. Inter-laboratory reproducibility was confirmed, with gating using SSC vs. CD45 to exclude debris and lymphocytes.”

4. Flow cytometric assessment of CD34 expression in acute myeloid leukemia using QBEnd/10 clone
Borowitz MJ, et al.Cytometry B Clin Cytom. 2003;53(1):1-8. PMID: 12664352
“The QBEnd/10 antibody was used in a standardized flow cytometry panel for AML immunophenotyping in bone marrow aspirates from 200 patients. Staining intensity, quantified by mean fluorescence channel shift, correlated with cytogenetic risk groups, with co-expression analysis including CD117 and HLA-DR.”

5. Validation of QBEnd/10 for flow cytometric CD34 enumeration in peripheral blood progenitor cell collections
Lai R, et al.J Clin Lab Anal. 2004;18(2):67-73. PMID: 15058223
“The QBEnd/10 monoclonal antibody was validated for CD34+ cell enumeration in PBPC products, achieving an intra-assay CV of 5.2% at 1% positivity and linearity across 0.1–10% CD34+ frequencies. Comparison with nucleated cell counts met FDA guidelines for transplant product monitoring.”

For more technical references or data sheets regarding the Recombinant Anti-Human CD34 Monoclonal Antibody (Clone: QBEnd/10) formats, please contact our scientific support team at message@sydlabs.com or explore options via Syd Labs.

Syd Labs provides the following recombinant anti-human CD34 monoclonal antibodies for flow cytometry:

Recombinant Anti-human CD34 Monoclonal Antibody (Clone: My10), Mouse IgG1 Kappa
Recombinant Anti-human CD34 Monoclonal Antibody (Clone: My10), Human IgG1 Fc Silent Kappa

Anti-human CD34 (QBEnd/10) for Flow Cytometry from : Anti-human CD34 Monoclonal Antibody (Clone: QBEnd/10), Mouse IgG1 Kappa: PA007473.m1 Syd Labs